PCB TOOLS / Electronics reference

IP Ratings: Solids, Water and the 9/9K Distinction

Read the two IP characteristic numerals and distinguish an undeclared X, dust/water tests and K markings in automotive ISO 20653 versus IEC 60529.

Quick answer

The first numeral covers access/solid-object protection and the second harmful water ingress. X means no rating is declared for that position, not zero. IPX8 has specified agreed depth/time conditions, not a universal 3 m maximum. Read IPX9 and IPX9K with their respective standards.

Scope

The archive retains two notation rows, seven solid and eleven liquid entries. The liquid table mixes IEC and automotive K entries and summarizes procedures. It does not specify a complete certification test or establish chemical, saltwater, ageing, drop or permanent underwater suitability.

Reading example

IPX7 declares the immersion rating while leaving the first numeral undeclared; IP67 also declares solid level 6. An IPX8 claim alone does not establish IPX5/IPX6 jet testing; look for additional declared ratings.

Checked reference tables

The numeral 9 still needs its standard
MarkingStandard contextReading limit
IPX9IEC 60529Use the referenced IEC edition; not merely a renamed archived 9K row.
IPX9K / IPX6KISO 20653Automotive K conditions must not be merged into IEC entries without identifying the standard.
IPX8IEC 60529State the specified/agreed immersion depth, duration and product conditions.

Legacy tables with visible corrections

IP XY code

IP Ratings: Solids, Water and the 9/9K Distinction · archived table 1
Position variablePropertyArchived numeral range
XSolid particle protectionnumber 0‑6
YLiquid ingress protectionnumber 0‑9

Solid particle protection

IP Ratings: Solids, Water and the 9/9K Distinction · archived table 2
LevelProtected against (object size)Effective against
0-No protection
1>50 mmLarge surfaces
2>12.5 mmFingers or similar objects
3>2.5 mmTools, thick wires, etc.
4>1 mmMost wires, screws, etc.
5Dust protectedIngress of some dust
6Dust tightNo ingress of dust

Liquid ingress protection

IP Ratings: Solids, Water and the 9/9K Distinction · archived table 3
LevelProtected againstEffective against
0-No protection
1Dripping waterVertically falling drops (1 mm rainfall per minute)
2Dripping water when tilted up to 15°Vertically dripping water when the enclosure is tilted up to 15° (3 mm rainfall per minute)
3Spraying waterWater falling as a spray at any angle up to 60° (0.7 l/min at 80‑100 kPa)
4Splashing of waterWater splashing from any direction (10 l/min at 80‑100 kPa)
5Water jetsWater projected by a nozzle from any direction (12.5 l/min at 30 kPa at a distance of 3 m)
6Powerful water jetsWater projected in powerful jets from any direction (100 l/min at 100 kPa at a distance of 3 m)
6KPowerful water jets with increased pressureWater projected in powerful jets from any direction under elevated pressure (75 l/min at 1000 kPa at a distance of 3 m)
7Immersion up to 1 mSubmersion in water up to 1 m for 30 minutes
8Immersion beyond 1 mContinuous immersion under specified/agreed depth, time and conditions; no universal 3 m maximum.Legacy record: “Continuous immersion in water at a depth generally up to 3 m (water can enter but only in such a manner that it produces no harmful effects)”. The archived “generally up to 3 m” is not a universal IPX8 condition.
9KPowerful high temperature water jetsAutomotive 9K historical summary: approximately 0.1–0.15 m, 80 °C, 14–16 L/min and 8–10 MPa; verify the applicable ISO 20653 edition, not a complete IEC IPX9 procedure.Legacy record: “Protected against close‑range high pressure, high temperature spray downs (14‑16 l/min at 8000‑10000 kPa at a distance of 0.1‑0.15 cm, 80 °C)”. The source distance unit cm is erroneous; the two standards must remain distinct.
Legacy source notes and applicability

These notes retain the legacy record. For corrected facts and applicability, use this page’s quick answer, scope and visible table corrections.

Ingress Protection Marking
IP XY code
Solid particle protection
Liquid ingress protection

Frequently asked questions

Does a higher water numeral include every lower test?

Do not assume this, particularly across jet and immersion tests. Check the standard relationship and the product’s separately declared ratings.

Does IP68 permit hot shower use?

The code alone does not establish hot water, steam, detergent, pressure transients or seal-ageing performance. Follow the product’s stated use and test conditions.

Related tools and references

Sources and verification

Legacy baseline: the Electrodoc Pro 5.2 data package. Raw records are retained and checked factual corrections are shown explicitly.