PCB TOOLS / Electronics reference
IP Ratings: Solids, Water and the 9/9K Distinction
Read the two IP characteristic numerals and distinguish an undeclared X, dust/water tests and K markings in automotive ISO 20653 versus IEC 60529.
Quick answer
The first numeral covers access/solid-object protection and the second harmful water ingress. X means no rating is declared for that position, not zero. IPX8 has specified agreed depth/time conditions, not a universal 3 m maximum. Read IPX9 and IPX9K with their respective standards.
Scope
The archive retains two notation rows, seven solid and eleven liquid entries. The liquid table mixes IEC and automotive K entries and summarizes procedures. It does not specify a complete certification test or establish chemical, saltwater, ageing, drop or permanent underwater suitability.
Reading example
IPX7 declares the immersion rating while leaving the first numeral undeclared; IP67 also declares solid level 6. An IPX8 claim alone does not establish IPX5/IPX6 jet testing; look for additional declared ratings.
Checked reference tables
| Marking | Standard context | Reading limit |
|---|---|---|
| IPX9 | IEC 60529 | Use the referenced IEC edition; not merely a renamed archived 9K row. |
| IPX9K / IPX6K | ISO 20653 | Automotive K conditions must not be merged into IEC entries without identifying the standard. |
| IPX8 | IEC 60529 | State the specified/agreed immersion depth, duration and product conditions. |
Legacy tables with visible corrections
IP XY code
| Position variable | Property | Archived numeral range |
|---|---|---|
| X | Solid particle protection | number 0‑6 |
| Y | Liquid ingress protection | number 0‑9 |
Solid particle protection
| Level | Protected against (object size) | Effective against |
|---|---|---|
| 0 | - | No protection |
| 1 | >50 mm | Large surfaces |
| 2 | >12.5 mm | Fingers or similar objects |
| 3 | >2.5 mm | Tools, thick wires, etc. |
| 4 | >1 mm | Most wires, screws, etc. |
| 5 | Dust protected | Ingress of some dust |
| 6 | Dust tight | No ingress of dust |
Liquid ingress protection
| Level | Protected against | Effective against |
|---|---|---|
| 0 | - | No protection |
| 1 | Dripping water | Vertically falling drops (1 mm rainfall per minute) |
| 2 | Dripping water when tilted up to 15° | Vertically dripping water when the enclosure is tilted up to 15° (3 mm rainfall per minute) |
| 3 | Spraying water | Water falling as a spray at any angle up to 60° (0.7 l/min at 80‑100 kPa) |
| 4 | Splashing of water | Water splashing from any direction (10 l/min at 80‑100 kPa) |
| 5 | Water jets | Water projected by a nozzle from any direction (12.5 l/min at 30 kPa at a distance of 3 m) |
| 6 | Powerful water jets | Water projected in powerful jets from any direction (100 l/min at 100 kPa at a distance of 3 m) |
| 6K | Powerful water jets with increased pressure | Water projected in powerful jets from any direction under elevated pressure (75 l/min at 1000 kPa at a distance of 3 m) |
| 7 | Immersion up to 1 m | Submersion in water up to 1 m for 30 minutes |
| 8 | Immersion beyond 1 m | Continuous immersion under specified/agreed depth, time and conditions; no universal 3 m maximum.Legacy record: “Continuous immersion in water at a depth generally up to 3 m (water can enter but only in such a manner that it produces no harmful effects)”. The archived “generally up to 3 m” is not a universal IPX8 condition. |
| 9K | Powerful high temperature water jets | Automotive 9K historical summary: approximately 0.1–0.15 m, 80 °C, 14–16 L/min and 8–10 MPa; verify the applicable ISO 20653 edition, not a complete IEC IPX9 procedure.Legacy record: “Protected against close‑range high pressure, high temperature spray downs (14‑16 l/min at 8000‑10000 kPa at a distance of 0.1‑0.15 cm, 80 °C)”. The source distance unit cm is erroneous; the two standards must remain distinct. |
Legacy source notes and applicability
These notes retain the legacy record. For corrected facts and applicability, use this page’s quick answer, scope and visible table corrections.
IP XY code
Solid particle protection
Liquid ingress protection
Frequently asked questions
Does a higher water numeral include every lower test?
Do not assume this, particularly across jet and immersion tests. Check the standard relationship and the product’s separately declared ratings.
Does IP68 permit hot shower use?
The code alone does not establish hot water, steam, detergent, pressure transients or seal-ageing performance. Follow the product’s stated use and test conditions.
Related tools and references
Sources and verification
Legacy baseline: the Electrodoc Pro 5.2 data package. Raw records are retained and checked factual corrections are shown explicitly.