PCB TOOLS / PINOUT & INTERFACE REFERENCE

Ethernet Pinout: T568A, T568B and Crossover Wiring

Compare 8P8C contacts, twisted pairs, T568A/T568B colors and Ethernet signals, including two-pair and four-pair crossover references.

Quick answer

T568A and T568B exchange the orange and green pairs: T568A uses white/green and green on 1/2, and white/orange and orange on 3/6; T568B reverses these pairs. Both use blue/white-blue on 4/5 and white-brown/brown on 7/8.

Scope

The two-pair TX/RX labels use the conventional 10BASE-T/100BASE-TX MDI reference; MDI-X differs. 1000BASE-T uses all four bidirectional pairs. A correct wire map does not certify bandwidth, reach, shielding or PoE capability.

Reading example

A T568B straight-through cable uses 1 white/orange, 2 orange, 3 white/green, 4 blue, 5 white/blue, 6 green, 7 white/brown and 8 brown at both ends. Match contact numbers and orientation; a jack’s rear termination layout need not match its front order.

Checked reference tables

T568A/T568B wire-color text reference
ContactT568A colorT568B color
1white/greenwhite/orange
2greenorange
3white/orangewhite/green
4blueblue
5white/bluewhite/blue
6orangegreen
7white/brownwhite/brown
8brownbrown

Interfaces, pinouts and technical reference

Ethernet EIA/TIA-568A/B

Original T568A wire-color numbering signal-numbering diagram
Original T568A wire-color numbering functional numbering map; verify actual pin 1 and view. Not a mechanical view.
Original T568B wire-color numbering signal-numbering diagram
Original T568B wire-color numbering functional numbering map; verify actual pin 1 and view. Not a mechanical view.
Table 1 · Ethernet EIA/TIA-568A/B
PinPairSignalWireColor
T568AT568B10/100 Base-T1000 Base-TT568AT568B
132TX+BI_DA++/tipwhite/greenwhite/greenwhite/orangewhite/orange
232TX-BI_DA--/ringgreengreenorangeorange
323RX+BI_DB++/tipwhite/orangewhite/orangewhite/greenwhite/green
411BI_DC+-/ringblueblueblueblue
511BI_DC-+/tipwhite/bluewhite/bluewhite/bluewhite/blue
623RX-BI_DB--/ringorangeorangegreengreen
744BI_DD++/tipwhite/brownwhite/brownwhite/brownwhite/brown
844BI_DD--/ringbrownbrownbrownbrown
Original T568A wire-color numbering signal-numbering diagram
Original T568A wire-color numbering functional numbering map; verify actual pin 1 and view. Not a mechanical view.
Original T568A other-end numbering signal-numbering diagram
Original T568A other-end numbering functional numbering map; verify actual pin 1 and view. Not a mechanical view.
Original T568B wire-color numbering signal-numbering diagram
Original T568B wire-color numbering functional numbering map; verify actual pin 1 and view. Not a mechanical view.
Original T568B other-end numbering signal-numbering diagram
Original T568B other-end numbering functional numbering map; verify actual pin 1 and view. Not a mechanical view.

Cross-over cable pinouts

Original T568B wire-color numbering signal-numbering diagram
Original T568B wire-color numbering functional numbering map; verify actual pin 1 and view. Not a mechanical view.
Original T568A other-end numbering signal-numbering diagram
Original T568A other-end numbering functional numbering map; verify actual pin 1 and view. Not a mechanical view.
Table 5 · Cross-over cable pinouts
PinConnection 1: T568AConnection 2: T568B
signalpaircolorsignalpaircolor
1BI_DA+3white/greenwhite/greenBI_DB+2white/orangewhite/orange
2BI_DA-3greengreenBI_DB-2orangeorange
3BI_DB+2white/orangewhite/orangeBI_DA+3white/greenwhite/green
41blueblue1blueblue
51white/bluewhite/blue1white/bluewhite/blue
6BI_DB-2orangeorangeBI_DA-3greengreen
74white/brownwhite/brown4white/brownwhite/brown
84brownbrown4brownbrown
Table 6 · Cross-over cable pinouts
PinConnection 1: T568AConnection 2: T568A Crossed
signalpaircolorsignalpaircolor
1BI_DA+3white/greenwhite/greenBI_DB+2white/orangewhite/orange
2BI_DA-3greengreenBI_DB-2orangeorange
3BI_DB+2white/orangewhite/orangeBI_DA+3white/greenwhite/green
4BI_DC+1blueblueBI_DD+4white/brownwhite/brown
5BI_DC-1white/bluewhite/blueBI_DD-4brownbrown
6BI_DB-2orangeorangeBI_DA-3greengreen
7BI_DD+4white/brownwhite/brownBI_DC+1blueblue
8BI_DD-4brownbrownBI_DC-1white/bluewhite/blue
Table 7 · Cross-over cable pinouts
PinConnection 1: T568BConnection 2: T568B Crossed
signalpaircolorsignalpaircolor
1BI_DA+2white/orangewhite/orangeBI_DB+3white/greenwhite/green
2BI_DA-2orangeorangeBI_DB-3greengreen
3BI_DB+3white/greenwhite/greenBI_DA+2white/orangewhite/orange
4BI_DC+1blueblueBI_DD+4white/brownwhite/brown
5BI_DC-1white/bluewhite/blueBI_DD-4brownbrown
6BI_DB-3greengreenBI_DA-2orangeorange
7BI_DD+4white/brownwhite/brownBI_DC+1blueblue
8BI_DD-4brownbrownBI_DC-1white/bluewhite/blue

Ethernet over twisted pair standards

Table 8 · Ethernet over twisted pair standards
NameStandardSpeed (Mbit/s)Bandwidth (MHz)Cable req. per 100m
10BASE-T802.3i 19901010Cat 3
100BASE-TX802.3u 199510031.25Cat 5
1000BASE-T802.3ab 1999100062.5Cat 5e
2.5GBASE-T802.3bz 20162500100Cat 5e
5GBASE-T5000200Cat 6
10GBASE-T802.3an 200610000400Cat 6A
25GBASE-T802.3bq 2016250001000Cat 8; maximum 30 m channel (two connectors)Legacy record: “Cat 8”. Fluke specifies a 30 m, two-connector Cat 8 channel. The source’s “per 100m” heading does not apply to this rate; the Cat 8 category is retained.
40GBASE-T400001600Cat 8; maximum 30 m channel (two connectors)Legacy record: “Cat 8”. Fluke specifies a 30 m, two-connector Cat 8 channel. The source’s “per 100m” heading does not apply to this rate; the Cat 8 category is retained.
Legacy source notes and applicability

These notes retain the legacy record. For corrected facts and applicability, use this page’s quick answer, scope and visible table corrections.

Ethernet EIA/TIA-568A/B
white/green
white/orange
green
orange
blue
white/blue
white/brown
brown
Direct Connection EIA/TIA-568A
Direct Connection EIA/TIA-568B
Cross-over cable pinouts
Cross-over cable EIA/TIA-568A/B (10Base-T, 100Base-TX)
10BASE-T or 100BASE-TX crossover
Gigabit T568A crossover
Gigabit T568B crossover
Ethernet over twisted pair standards

Frequently asked questions

Does Auto-MDI-X allow arbitrary wiring?

No. It handles supported straight/crossover relationships. Pair integrity, continuity, termination quality and category performance still matter; follow the device’s enablement requirements.

Is T568A faster than T568B?

Neither assignment is inherently faster. Follow the installation’s chosen scheme consistently; cable, connector, installation and PHY capabilities determine operation.

Related tools and references

Sources and verification

Legacy baseline: the Electrodoc Pro 5.2 data package. Raw records are retained and checked factual corrections are shown explicitly.