PCB TOOLS / PINOUT & INTERFACE REFERENCE
Ethernet Pinout: T568A, T568B and Crossover Wiring
Compare 8P8C contacts, twisted pairs, T568A/T568B colors and Ethernet signals, including two-pair and four-pair crossover references.
Quick answer
T568A and T568B exchange the orange and green pairs: T568A uses white/green and green on 1/2, and white/orange and orange on 3/6; T568B reverses these pairs. Both use blue/white-blue on 4/5 and white-brown/brown on 7/8.
Scope
The two-pair TX/RX labels use the conventional 10BASE-T/100BASE-TX MDI reference; MDI-X differs. 1000BASE-T uses all four bidirectional pairs. A correct wire map does not certify bandwidth, reach, shielding or PoE capability.
Reading example
A T568B straight-through cable uses 1 white/orange, 2 orange, 3 white/green, 4 blue, 5 white/blue, 6 green, 7 white/brown and 8 brown at both ends. Match contact numbers and orientation; a jack’s rear termination layout need not match its front order.
Checked reference tables
| Contact | T568A color | T568B color |
|---|---|---|
| 1 | white/green | white/orange |
| 2 | green | orange |
| 3 | white/orange | white/green |
| 4 | blue | blue |
| 5 | white/blue | white/blue |
| 6 | orange | green |
| 7 | white/brown | white/brown |
| 8 | brown | brown |
Interfaces, pinouts and technical reference
Ethernet EIA/TIA-568A/B


| Pin | Pair | Signal | Wire | Color | |||
|---|---|---|---|---|---|---|---|
| T568A | T568B | 10/100 Base-T | 1000 Base-T | T568A | T568B | ||
| 1 | 3 | 2 | TX+ | BI_DA+ | +/tip | white/green | white/orange |
| 2 | 3 | 2 | TX- | BI_DA- | -/ring | green | orange |
| 3 | 2 | 3 | RX+ | BI_DB+ | +/tip | white/orange | white/green |
| 4 | 1 | 1 | BI_DC+ | -/ring | blue | blue | |
| 5 | 1 | 1 | BI_DC- | +/tip | white/blue | white/blue | |
| 6 | 2 | 3 | RX- | BI_DB- | -/ring | orange | green |
| 7 | 4 | 4 | BI_DD+ | +/tip | white/brown | white/brown | |
| 8 | 4 | 4 | BI_DD- | -/ring | brown | brown | |




Cross-over cable pinouts


| Pin | Connection 1: T568A | Connection 2: T568B | ||||
|---|---|---|---|---|---|---|
| signal | pair | color | signal | pair | color | |
| 1 | BI_DA+ | 3 | white/green | BI_DB+ | 2 | white/orange |
| 2 | BI_DA- | 3 | green | BI_DB- | 2 | orange |
| 3 | BI_DB+ | 2 | white/orange | BI_DA+ | 3 | white/green |
| 4 | 1 | blue | 1 | blue | ||
| 5 | 1 | white/blue | 1 | white/blue | ||
| 6 | BI_DB- | 2 | orange | BI_DA- | 3 | green |
| 7 | 4 | white/brown | 4 | white/brown | ||
| 8 | 4 | brown | 4 | brown | ||
| Pin | Connection 1: T568A | Connection 2: T568A Crossed | ||||
|---|---|---|---|---|---|---|
| signal | pair | color | signal | pair | color | |
| 1 | BI_DA+ | 3 | white/green | BI_DB+ | 2 | white/orange |
| 2 | BI_DA- | 3 | green | BI_DB- | 2 | orange |
| 3 | BI_DB+ | 2 | white/orange | BI_DA+ | 3 | white/green |
| 4 | BI_DC+ | 1 | blue | BI_DD+ | 4 | white/brown |
| 5 | BI_DC- | 1 | white/blue | BI_DD- | 4 | brown |
| 6 | BI_DB- | 2 | orange | BI_DA- | 3 | green |
| 7 | BI_DD+ | 4 | white/brown | BI_DC+ | 1 | blue |
| 8 | BI_DD- | 4 | brown | BI_DC- | 1 | white/blue |
| Pin | Connection 1: T568B | Connection 2: T568B Crossed | ||||
|---|---|---|---|---|---|---|
| signal | pair | color | signal | pair | color | |
| 1 | BI_DA+ | 2 | white/orange | BI_DB+ | 3 | white/green |
| 2 | BI_DA- | 2 | orange | BI_DB- | 3 | green |
| 3 | BI_DB+ | 3 | white/green | BI_DA+ | 2 | white/orange |
| 4 | BI_DC+ | 1 | blue | BI_DD+ | 4 | white/brown |
| 5 | BI_DC- | 1 | white/blue | BI_DD- | 4 | brown |
| 6 | BI_DB- | 3 | green | BI_DA- | 2 | orange |
| 7 | BI_DD+ | 4 | white/brown | BI_DC+ | 1 | blue |
| 8 | BI_DD- | 4 | brown | BI_DC- | 1 | white/blue |
Ethernet over twisted pair standards
| Name | Standard | Speed (Mbit/s) | Bandwidth (MHz) | Cable req. per 100m |
|---|---|---|---|---|
| 10BASE-T | 802.3i 1990 | 10 | 10 | Cat 3 |
| 100BASE-TX | 802.3u 1995 | 100 | 31.25 | Cat 5 |
| 1000BASE-T | 802.3ab 1999 | 1000 | 62.5 | Cat 5e |
| 2.5GBASE-T | 802.3bz 2016 | 2500 | 100 | Cat 5e |
| 5GBASE-T | 5000 | 200 | Cat 6 | |
| 10GBASE-T | 802.3an 2006 | 10000 | 400 | Cat 6A |
| 25GBASE-T | 802.3bq 2016 | 25000 | 1000 | Cat 8; maximum 30 m channel (two connectors)Legacy record: “Cat 8”. Fluke specifies a 30 m, two-connector Cat 8 channel. The source’s “per 100m” heading does not apply to this rate; the Cat 8 category is retained. |
| 40GBASE-T | 40000 | 1600 | Cat 8; maximum 30 m channel (two connectors)Legacy record: “Cat 8”. Fluke specifies a 30 m, two-connector Cat 8 channel. The source’s “per 100m” heading does not apply to this rate; the Cat 8 category is retained. |
Legacy source notes and applicability
These notes retain the legacy record. For corrected facts and applicability, use this page’s quick answer, scope and visible table corrections.
white/green
white/orange
green
orange
blue
white/blue
white/brown
brown
Direct Connection EIA/TIA-568A
Direct Connection EIA/TIA-568B
Cross-over cable pinouts
Cross-over cable EIA/TIA-568A/B (10Base-T, 100Base-TX)
10BASE-T or 100BASE-TX crossover
Gigabit T568A crossover
Gigabit T568B crossover
Ethernet over twisted pair standards
Frequently asked questions
Does Auto-MDI-X allow arbitrary wiring?
No. It handles supported straight/crossover relationships. Pair integrity, continuity, termination quality and category performance still matter; follow the device’s enablement requirements.
Is T568A faster than T568B?
Neither assignment is inherently faster. Follow the installation’s chosen scheme consistently; cable, connector, installation and PHY capabilities determine operation.
Related tools and references
Sources and verification
- Fluke Networks: T568A/T568B pair assignments and viewing direction
- Eaton: InduTel IP4 manual, page 7 wire colors
- Fluke Networks: Category 8, 30 m channels and 2 GHz characterization
- Cisco: Auto-MDI-X operation and configuration restrictions
Legacy baseline: the Electrodoc Pro 5.2 data package. Raw records are retained and checked factual corrections are shown explicitly.
white/green
white/orange
green
orange
blue
white/blue
white/brown