Quick answer
1–4 and 13–16 carry DIO 1–8; 6DAV, 7 NRFD, 8 NDAC are handshake; 12 is shield and 24 logic ground.
Scope
Covers the common IEEE 48824-contact instrument interface; bus address is not contact number, and proper transceivers/controllers are required.The drawing does not define mechanical view.
Reading example
NRFD is 7 with paired return 19; 18–23 accompany DAV/NRFD/NDAC/IFC/SRQ/ATN respectively.
Legacy tables with visible corrections
| Pin | Name | Description |
|---|---|---|
| 1 | DIO1 | Data input/output bit 1 |
| 2 | DIO2 | Data input/output bit 2 |
| 3 | DIO3 | Data input/output bit 3 |
| 4 | DIO4 | Data input/output bit 4 |
| 5 | EOI | End-or-identify |
| 6 | DAV | Data valid |
| 7 | NRFD | Not ready for data |
| 8 | NDAC | Not data accepted |
| 9 | IFC | Interface clear |
| 10 | SRQ | Service request |
| 11 | ATN | Attention |
| 12 | SHIELD | Cable shield/chassis reference, not automatically PELegacy record: “Earth”. NI defines12 as Shield and 24 separately as Logic Ground; Earth overgeneralizes the source. |
| 13 | DIO5 | Data input/output bit 5 |
| 14 | DIO6 | Data input/output bit 6 |
| 15 | DIO7 | Data input/output bit 7 |
| 16 | DIO8 | Data input/output bit 8 |
| 17 | REN | Remote enable |
| 18 | GND | (wire twisted with DAV) |
| 19 | GND | (wire twisted with NRFD) |
| 20 | GND | (wire twisted with NDAC) |
| 21 | GND | (wire twisted with IFC) |
| 22 | GND | (wire twisted with SRQ) |
| 23 | GND | (wire twisted with ATN) |
| 24 | Signal GND | Ground |
Legacy source notes and applicability
These notes retain the legacy record. For corrected facts and applicability, use this page’s quick answer, scope and visible table corrections.
Frequently asked questions
Are SHIELD and Signal GND interchangeable?
Not from their names alone.12 and 24 have different roles; shield bonding follows the equipment EMC design.
Does device address5 mean contact 5?
No.Address is a protocol setting; contact 5 is EOI.
Related tools and references
Sources and verification
Legacy baseline: the Electrodoc Pro 5.2 data package. Raw records are retained and checked factual corrections are shown explicitly.