PCB TOOLS / Electronics reference
Resistor Preferred Values: E6, E12, E24, E48, E96 and E192
Look up nominal values in six E-series, interpret the table’s base-100 coefficients and distinguish series density from tolerance. Compare the values with the site’s preferred-value calculators.
Quick answer
E24 provides 24 nominal values per decade and E192 provides 192. Entries use a base of 100: 470 represents 4.70×10ⁿ Ω, for example 4.7 kΩ. A series defines a nominal-value set; it does not require every component to have the tolerance printed in the legacy heading.
Scope
Use this reference for resistor nominal values and comparisons between series. Ideal geometric spacing is vᵢ=10^(i/N), i=0…N−1. Use published series values for selection: historical rounding and adjustments, especially in E6/E12/E24, prevent simple rounding of that expression from reproducing the full IEC table. Blank cells mean that the sparser series does not include that row.
Reading example
E24 entry 470 can represent 470 Ω, 4.7 kΩ or 47 kΩ by decade scaling. The site’s relative-error search maps an E24 target of 5000 Ω to 5100 Ω and preserves 4700 Ω. The legacy E192 table incorrectly printed 378 for 374; the checked table displays 374, matching both the package and site calculation series. A target of 378 Ω still selects 379 Ω in E192, with no algorithm change.
Legacy tables with visible corrections
| E6 (±20%) | E12 (±10%) | E24 (±5%) | E48 (±2%) | E96 (±1%) | E192 (±0.5%) |
|---|---|---|---|---|---|
| 100 | 100 | 100 | 100 | 100 | 100 |
| 101 | |||||
| 102 | 102 | ||||
| 104 | |||||
| 105 | 105 | 105 | |||
| 106 | |||||
| 107 | 107 | ||||
| 109 | |||||
| 110 | 110 | 110 | 110 | ||
| 111 | |||||
| 113 | 113 | ||||
| 114 | |||||
| 115 | 115 | 115 | |||
| 117 | |||||
| 118 | 118 | ||||
| 120 | 120 | 120 | |||
| 121 | 121 | 121 | |||
| 123 | |||||
| 124 | 124 | ||||
| 126 | |||||
| 127 | 127 | 127 | |||
| 129 | |||||
| 130 | 130 | 130 | |||
| 132 | |||||
| 133 | 133 | 133 | |||
| 135 | |||||
| 137 | 137 | ||||
| 138 | |||||
| 140 | 140 | 140 | |||
| 142 | |||||
| 143 | 143 | ||||
| 145 | |||||
| 147 | 147 | 147 | |||
| 149 | |||||
| 150 | 150 | 150 | 150 | 150 | |
| 152 | |||||
| 154 | 154 | 154 | |||
| 156 | |||||
| 158 | 158 | ||||
| 160 | 160 | ||||
| 162 | 162 | 162 | |||
| 164 | |||||
| 165 | 165 | ||||
| 167 | |||||
| 169 | 169 | 169 | |||
| 172 | |||||
| 174 | 174 | ||||
| 176 | |||||
| 178 | 178 | 178 | |||
| 180 | 180 | 180 | |||
| 182 | 182 | ||||
| 184 | |||||
| 187 | 187 | 187 | |||
| 189 | |||||
| 191 | 191 | ||||
| 193 | |||||
| 196 | 196 | 196 | |||
| 198 | |||||
| 200 | 200 | 200 | |||
| 203 | |||||
| 205 | 205 | 205 | |||
| 208 | |||||
| 210 | 210 | ||||
| 213 | |||||
| 215 | 215 | 215 | |||
| 218 | |||||
| 220 | 220 | 220 | 221 | 221 | |
| 223 | |||||
| 226 | 226 | 226 | |||
| 229 | |||||
| 232 | 232 | ||||
| 234 | |||||
| 237 | 237 | 237 | |||
| 240 | 240 | ||||
| 243 | 243 | ||||
| 246 | |||||
| 249 | 249 | 249 | |||
| 252 | |||||
| 255 | 255 | ||||
| 258 | |||||
| 261 | 261 | 261 | |||
| 264 | |||||
| 267 | 267 | ||||
| 270 | 270 | 271 | |||
| 274 | 274 | 274 | |||
| 277 | |||||
| 280 | 280 | ||||
| 284 | |||||
| 287 | 287 | 287 | |||
| 291 | |||||
| 294 | 294 | ||||
| 298 | |||||
| 300 | 301 | 301 | 301 | ||
| 305 | |||||
| 309 | 309 | ||||
| 312 | |||||
| 316 | 316 | 316 | |||
| 320 | |||||
| 324 | 324 | ||||
| 328 | |||||
| 330 | 330 | 330 | 332 | 332 | 332 |
| 336 | |||||
| 340 | 340 | ||||
| 344 | |||||
| 348 | 348 | 348 | |||
| 352 | |||||
| 357 | 357 | ||||
| 360 | 361 | ||||
| 365 | 365 | 365 | |||
| 370 | |||||
| 374 | 374Legacy record: “378”. The source value 378 is a transcription error. Vishay’s E192 table and this package’s series.json both contain 374. The raw record is retained. | ||||
| 379 | |||||
| 383 | 383 | 383 | |||
| 388 | |||||
| 390 | 390 | 392 | 392 | ||
| 397 | |||||
| 402 | 402 | 402 | |||
| 407 | |||||
| 412 | 412 | ||||
| 417 | |||||
| 422 | 422 | 422 | |||
| 427 | |||||
| 430 | 432 | 432 | |||
| 437 | |||||
| 442 | 442 | 442 | |||
| 448 | |||||
| 453 | 453 | ||||
| 459 | |||||
| 464 | 464 | 464 | |||
| 470 | 470 | 470 | 470 | ||
| 475 | 475 | ||||
| 481 | |||||
| 487 | 487 | 487 | |||
| 493 | |||||
| 499 | 499 | ||||
| 505 | |||||
| 510 | 511 | 511 | 511 | ||
| 517 | |||||
| 523 | 523 | ||||
| 530 | |||||
| 536 | 536 | 536 | |||
| 542 | |||||
| 549 | 549 | ||||
| 556 | |||||
| 560 | 560 | 562 | 562 | 562 | |
| 569 | |||||
| 576 | 576 | ||||
| 583 | |||||
| 590 | 590 | 590 | |||
| 597 | |||||
| 604 | 604 | ||||
| 612 | |||||
| 619 | 619 | 619 | |||
| 620 | 626 | ||||
| 634 | 634 | ||||
| 642 | |||||
| 649 | 649 | 649 | |||
| 657 | |||||
| 665 | 665 | ||||
| 673 | |||||
| 680 | 680 | 680 | 681 | 681 | 681 |
| 690 | |||||
| 698 | 698 | ||||
| 706 | |||||
| 715 | 715 | 715 | |||
| 723 | |||||
| 732 | 732 | ||||
| 741 | |||||
| 750 | 750 | 750 | 750 | ||
| 759 | |||||
| 768 | 768 | ||||
| 777 | |||||
| 787 | 787 | 787 | |||
| 796 | |||||
| 806 | 806 | ||||
| 816 | |||||
| 820 | 820 | 825 | 825 | 825 | |
| 835 | |||||
| 845 | 845 | ||||
| 856 | |||||
| 866 | 866 | 866 | |||
| 876 | |||||
| 887 | 887 | ||||
| 898 | |||||
| 909 | 909 | 909 | |||
| 910 | 920 | ||||
| 931 | 931 | ||||
| 942 | |||||
| 953 | 953 | 953 | |||
| 965 | |||||
| 976 | 976 | ||||
| 988 |
Legacy source notes and applicability
These notes retain the legacy record. For corrected facts and applicability, use this page’s quick answer, scope and visible table corrections.
Val = d x 10⁽i/N⁾where:
d = decate multiplier (1, 10, 100, 1000, etc)
i = 0...(N-1)
N = series (12, 24, 48, 96, 192)
Frequently asked questions
Why does E24 omit many integer values?
It selects 24 nominal points per decade for production, range coverage and stocking. E48/E96/E192 offer finer nominal spacing; availability and ratings still depend on the part.
Is an E96 resistor necessarily more accurate than E24?
No. The E-series specifies nominal values. Tolerance, temperature coefficient, drift and power rating are separate component parameters. The same 1 kΩ nominal value can have several tolerance grades.
Related tools and references
Sources and verification
- Vishay: Standard Ohmic Values, including E192 value 374
- Vishay Dale: decade values and common tolerances
- Vishay: D/CRCW data sheet, values, tolerances and rating conditions
Legacy baseline: the Electrodoc Pro 5.2 data package. Raw records are retained and checked factual corrections are shown explicitly.