Transformer Turns Ratio Calculator

Calculate the turns ratio n, secondary turns N₂, secondary current I₂, Volts-per-turn, and required core cross-sectional area Ae.

Primary Winding Parameters

Secondary Winding Parameters

Core Parameters (Optional)

Silicon steel: 1.0–1.5 T; Ferrite: 0.3–0.4 T

Results

Turns Ratio n = N₁/N₂
Secondary Turns N₂ turns
Secondary Current I₂ A
Apparent Power Rating VA
Volts per Turn (V/turn) V/turn
Required Core Area Ae cm²

Formulas

n = V₁ / V₂ = N₁ / N₂ = I₂ / I₁

N₂ = N₁ × (V₂ / V₁)

Ae = V₁ / (4.44 × f × N₁ × Bmax)